COMMUNICATION
Each XR5 panel contains a built-in dual
phone line module with line supervision
that can communicate to one or two
remote receivers using DMP Serial 3
digital dialer, Contact ID (CID), or 4-2
formats. You can also selectively enable
alarm, supervisory/trouble, backup, and
recall test reporting to either of the two
receivers.
NETWORK MONITORING™
An iCOMSL Network Alarm Communicator
connects to the XR5 to provide Internet/
LAN/WAN communications to the panel.
When used in this manner or as a slave
or stand-alone network communicator,
the iCOMSL reduces or eliminates costly
telephone lines and communicates to the
central station via high-speed network
connections.
ONE-MAN WALK TEST
Conduct one-man tests of the system and
all connected devices using the Walk Test
feature. Simply enter an access code into
the keypad and XR5 panels automatically
enter test mode. Each time a zone
trips during the test, the bell rings
for two seconds and a Sensor Reset is
automatically performed to reset latched
detectors. When the test is completed,
the results display at the keypad and can
be sent to the central station.
POWERFUL FALSE ALARM
REDUCTION FEATURES
The built-in false alarm reduction
features include cross zoning, fire
verication, re retard, and CleanMe™
reporting.
Cross zoning allows multiple zones to
be cross zoned and reports alarms only
when two or more zones fault within a
programmable time of 4 to 250 seconds.
Should just one zone trip, only a zone
fault report is sent to the central
station.
Fire verication provides a 120-second
window during which a smoke detector
can trip, be automatically reset, and
then must trip a second time before an
alarm is indicated. A single trip on the
zone sends only a zone fault report to
the central station.
Fire retard allows a programmable time
of up to 250 seconds for waterflow
detection. This eliminates the need
for additional mechanical delays at the
owswitch.
ANNUNCIATOR OUTPUTS
Four open collector outputs can be
used for a variety of remote control and
annunciation applications. Each output is
rated for 50mA maximum. Add the Model
860 Relay Output module to provide four
form C relay contacts. Each Model 305
relay is rated at 42mA and the module
easily mounts inside the XR5 enclosure.
TROUBLE ANNUNCIATOR
MODULE
For slave communicator applications,
the XR5SL provides an enclosure door-
mounted Model 377 Trouble Annunciator
Module. The Model 377 offers Trouble
and System OK LEDs with audible alert
and a Silence button for acknowledging
trouble conditions.
BUILT-IN PROGRAMMER
An internal English text Programmer
enables technicians to easily program
and test the panel from any keypad.
A lockout code restricts access to only
authorized persons.
REMOTE PROGRAMMING
Remotely program XR5 panels using
Remote Link™ programming software from
DMP. You can upload panel programming,
make the necessary programming
changes, and then download the revised
programming into the panel.
Expand Remote Link/System Link
functionality with Advance Reporting,
Alarm Monitoring, Command Center, or
Link Server packages.
VARIETY OF KEYPAD STYLES
For system annunciation, select from
several keypad styles to meet a variety
of re system requirements. The Model
692F LED keypad provides individual
alarm and trouble LEDs as well as
power, system trouble, and silenced
LEDs along with a full function, backlit
keyboard. You can also choose from
630F or 690F alphanumeric keypads.
Both LED and alphanumeric keypads
meet all requirements for local system
operation.