Digital Monitoring XR6 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Sicherheitszugriffskontrollsysteme Digital Monitoring XR6 herunter. Digital Monitoring XR6 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - PROGRAMMING GUIDE

PROGRAMMING GUIDEXR6 COMMAND PROCESSOR™ PANEL andXR10 COMMAND PROCESSOR™ PANEL

Seite 2 - MODEL XR6/XR10

2 - INITIALIZATIONDigital Monitoring Products XR6/XR10 Programming Guide42.1 INITIALIZATIONThis function allows you to set the panel's user codes

Seite 3 - TABLE OF CONTENTS

XR6/XR10 Programming Guide Digital Monitoring Products53 - COMMUNICATION3.1 COMMUNICATIONThis section allows you to configure the communication settin

Seite 4

3 - COMMUNICATIONDigital Monitoring Products XR6/XR10 Programming Guide63.11 OPENING/CLOSING AND USER REPORTSSelect YES to enable opening/closing, doo

Seite 5

XR6/XR10 Programming Guide Digital Monitoring Products73 - COMMUNICATION3.19 BACKUP REPORTINGYES enables this receiver to be a backup to the other rec

Seite 6

4 - REMOTE OPTIONSDigital Monitoring Products XR6/XR10 Programming Guide84.1 REMOTE OPTIONSThis section allows you to enter the information needed for

Seite 7 - 1.2 Getting Started

XR6/XR10 Programming Guide Digital Monitoring Products95 - SYSTEM REPORTS5.1 SYSTEM REPORTSThis section of the Programmer allows you to select the rep

Seite 8 - 1.6 Special Keys

6 - SYSTEM OPTIONSDigital Monitoring Products XR6/XR10 Programming Guide106.1 SYSTEM OPTIONSThis section allows you to select system-wide functions of

Seite 9 - 1.7 Entering Alpha Characters

XR6/XR10 Programming Guide Digital Monitoring Products117 - OUTPUT OPTIONS7.1 OUTPUT OPTIONSThis function allows you to program the panel's Bell

Seite 10 - 2 - INITIALIZATION

7 - OUTPUT OPTIONSDigital Monitoring Products XR6/XR10 Programming Guide127.5 OUTPUT ACTIONThis option allows you to define the operation of the panel

Seite 11 - 3 - COMMUNICATION

XR6/XR10 Programming Guide Digital Monitoring Products138 - ZONE INFORMATION8.1 ZONE INFORMATIONThis allows you to define the operation of each protec

Seite 12

MODEL XR6/XR10COMMAND PROCESSORPROGRAMMING GUIDE FCC NOTICEThis equipment generates and uses radio frequency energy and, if not installed and usedprop

Seite 13

8 - ZONE INFORMATIONDigital Monitoring Products XR6/XR10 Programming Guide148.6 ARM AREASThis option specifies the areas to be armed by the Arming Typ

Seite 14 - 4 - REMOTE OPTIONS

XR6/XR10 Programming Guide Digital Monitoring Products158 - ZONE INFORMATION8.9A MESSAGE TO TRANSMITYou can send two report types to the receiver: Ala

Seite 15 - 5 - SYSTEM REPORTS

8 - ZONE INFORMATIONDigital Monitoring Products XR6/XR10 Programming Guide168.11 ENTRY DELAYSelect the entry delay timer for this zone. Entry delay ti

Seite 16 - 6 - SYSTEM OPTIONS

XR6/XR10 Programming Guide Digital Monitoring Products179 - STOP9.1 STOPAt the STOP prompt, pressing any Select key allows you to exit the Programmer.

Seite 17 - 7 - OUTPUT OPTIONS

11 - APPENDIXDigital Monitoring Products XR6/XR10 Programming Guide1811.1 Status ListThe Status List is the current status of the system or records of

Seite 18

XR6/XR10 Programming Guide Digital Monitoring Products1911 - APPENDIX11.4 Zone Type SpecificationsThis section describes applications for the default

Seite 19 - 8 - ZONE INFORMATION

11 - APPENDIXDigital Monitoring Products XR6/XR10 Programming Guide2011.5 Zone Type DescriptionsNT (Night Zone) - Controlled instant zone used for per

Seite 20

XR6/XR10 Programming Guide Digital Monitoring Products2111 - APPENDIX11.7 Default panel programmingThis program sheets shows the XR6/XR10 panel's

Seite 21

11 - APPENDIXDigital Monitoring Products XR6/XR10 Programming Guide2211.8 4-2 Communication ReportsThe table below contains a complete list of hexadec

Seite 22

XR6/XR10 Programming Guide Digital Monitoring Products2311 - APPENDIX11.10 4-2 ExamplesThe following examples are the actual event codes a central sta

Seite 23 - 10 - SET LOCKOUT CODE

iiiDigital Monitoring Products XR6/XR10 Programming GuideTABLE OF CONTENTSPageSectionIntroduction1.1 Before You Begin...

Seite 24 - 11.1 Status List

INTRUSION • FIRE • ACCESS • NETWORKS2500 North Partnership Boulevard800-641-4282www.dmp.comMade in the USASpringfield, Missouri 65803-8877LT-023

Seite 25 - 11.4 Zone Type Specifications

XR6/XR10 Programming Guide Digital Monitoring ProductsivTABLE OF CONTENTSPageSectionSystem Reports5.1 SYSTEM REPORTS...

Seite 26 - 11.5 Zone Type Descriptions

vDigital Monitoring Products XR6/XR10 Programming GuideTABLE OF CONTENTSPageSectionZone Information8.1 ZONE INFORMATION ...

Seite 27

This page left intentionally blank.

Seite 28 - 11.9 How to Read this Table

XR6/XR10 Programming Guide Digital Monitoring Products11 - INTRODUCTION1.1 Before You BeginAbout this GuideThis guide provides programming information

Seite 29 - 11.10 4-2 Examples

1 - INTRODUCTIONDigital Monitoring Products XR6/XR10 Programming Guide21.3 Programming MenuTo select a section for programming, press any top row Sele

Seite 30 - Made in the USA

XR6/XR10 Programming Guide Digital Monitoring Products31 - INTRODUCTIONSelect KeysThe top row of keys are called the Select keys. When the Programmer

Kommentare zu diesen Handbüchern

Keine Kommentare